Re: Inaccurate Heat Bed Temp Display

Problem solved! Turned out there was some sort of residue that was bridging the connection. I went through and cleaned up the solder joints and it's now reading perfectly! I am extremely happy I don't have to unsolder and re-solder the thermistor. Although now my PEEK fan isn't running during the ...
by mpyr6
Tue Nov 25, 2014 9:48 pm
Forum: Rostock MAX v2
Topic: Inaccurate Heat Bed Temp Display
Replies: 8
Views: 5655

Re: Inaccurate Heat Bed Temp Display

So I have tested the resistance of the path from the plug itself and I get a rough reading of 84 at 200k ohms on the multimeter although the reading may not be accurate since I may have a bad multimeter. I have found that when left alone for an extended period of time the temperature drops back down ...
by mpyr6
Sun Nov 23, 2014 3:26 pm
Forum: Rostock MAX v2
Topic: Inaccurate Heat Bed Temp Display
Replies: 8
Views: 5655

Re: Inaccurate Heat Bed Temp Display

Ok, so since I don't have a Volt-Ohm Reader at my disposal this moment I decided to switch the hot end and bed connector on the board and the same thing is happening where now the hot end is reading hot. So I can conclude the issue is between the wire and the Thermistor. I will have to dive deeper ...
by mpyr6
Sun Nov 23, 2014 1:50 pm
Forum: Rostock MAX v2
Topic: PEEK Fan Shroud Overhang Curling
Replies: 4
Views: 3448

Re: PEEK Fan Shroud Overhang Curling

Thanks guys I will keep that in mind for future prints. I ended up just turning on supports and flipping it upside down. It worked well enough to use the shroud.
by mpyr6
Sun Nov 23, 2014 1:46 pm
Forum: Rostock MAX v2
Topic: Inaccurate Heat Bed Temp Display
Replies: 8
Views: 5655

Inaccurate Heat Bed Temp Display

I have printed with my Rostock a few times now but recently when the heat bed is heating the temperature will jump around from 61 degrees to 85 degrees and then back down to 61. It seems as though it reads the accurate temperature and then pops back to the wrong temp. When I turned on the printer ...
by mpyr6
Fri Nov 21, 2014 6:28 pm
Forum: Rostock MAX v2
Topic: Repeiter-Host to Matter Control
Replies: 5
Views: 3686

Re: Repeiter-Host to Matter Control

Thanks guys. I went ahead and ran the calibration with everything hot.

Here is a picture of the partial print I got for my first try!

http://i.imgur.com/6ZDDPRs.jpg
by mpyr6
Fri Nov 21, 2014 6:25 pm
Forum: Rostock MAX v2
Topic: PEEK Fan Shroud Overhang Curling
Replies: 4
Views: 3448

PEEK Fan Shroud Overhang Curling

I am trying to print the PEEK Fan Shroud and overall 90% of the print is coming out AMAZING. :D The biggest issue I am having is that once the print gets about 21mm from the print bed the overhang begins to curl upward and the hot end hits the curl and pushes the print out of place. This occurred ...
by mpyr6
Thu Nov 20, 2014 4:05 pm
Forum: Rostock MAX v2
Topic: Repeiter-Host to Matter Control
Replies: 5
Views: 3686

Repeiter-Host to Matter Control

I set up my Rostock Max v2 last night using the old manual and have configured the printer using Repeiter-Host. If I were to switch over to Matter Control could I use all of the EEPROM information from Repeiter-Host or must I run the tests again? Also, for the calibration process do I keep the hot ...

Go to advanced search