Search found 4 matches
- Wed Dec 19, 2018 12:59 am
- Forum: Troubleshooting
- Topic: Orion upgrade questions
- Replies: 5
- Views: 4530
Re: Orion upgrade questions
If memory serves it's around 6.8 ohms as tested at the crimp points where the resistor leads are joined together. If you upgrade to the HE280 hot end, you'll get auto-calibration. The HE280 has a sensor on the board that allows the whole hot end to be used as a Z probe. You can see what that ...
- Wed Dec 19, 2018 12:55 am
- Forum: Troubleshooting
- Topic: Orion upgrade questions
- Replies: 5
- Views: 4530
Re: Orion upgrade questions
Well, I tried loading Repetier 1.0.3 tonight. I used the online wizard with delta arm length and other values from the official SeeMeCNC firmware. After uploading, I found that the selector knob was reversed and significantly too sensitive. Not a big deal, I can work with that for now and fix it ...
- Tue Dec 11, 2018 4:59 pm
- Forum: Troubleshooting
- Topic: Orion upgrade questions
- Replies: 5
- Views: 4530
Re: Orion upgrade questions
If your Orion uses the older heating resistors (one on each "side" of the round heater block), there's no real gotchas with the firmware. However, if you have an Orion with the HE280 hot end that allows the Orion to auto-calibrate, you need to stick with the SeeMeCNC supplied firmware - the main ...
- Mon Dec 10, 2018 9:23 pm
- Forum: Troubleshooting
- Topic: Orion upgrade questions
- Replies: 5
- Views: 4530
Orion upgrade questions
Hi All! I recently purchased a used Orion Delta printer. I plugged it in, connected it to my OctoPi server and ran a couple of test prints after calibrating the Z axis stops. The first cube came out great printing ABS at 230C. On the second test with same settings and different model, it stopped ...