Search found 7 matches
- Mon Mar 11, 2019 11:35 am
- Forum: Troubleshooting
- Topic: Rostock v2 with probe keeps rebooting fw.92.2
- Replies: 11
- Views: 8520
Re: Rostock v2 with probe keeps rebooting fw.92.2
looks like everything is well connected, tested with the multimeter with the machine off, of course, there is connection between the pins 

- Sun Mar 10, 2019 1:56 pm
- Forum: Troubleshooting
- Topic: Rostock v2 with probe keeps rebooting fw.92.2
- Replies: 11
- Views: 8520
Re: Rostock v2 with probe keeps rebooting fw.92.2
so maybe the accelerometer is damaged?
- Sat Mar 09, 2019 11:51 pm
- Forum: Troubleshooting
- Topic: Rostock v2 with probe keeps rebooting fw.92.2
- Replies: 11
- Views: 8520
Re: Rostock v2 with probe keeps rebooting fw.92.2
same wiring, only difference was that I used other pair of cables
- Sat Mar 09, 2019 1:31 pm
- Forum: Troubleshooting
- Topic: Rostock v2 with probe keeps rebooting fw.92.2
- Replies: 11
- Views: 8520
Re: Rostock v2 with probe keeps rebooting fw.92.2
I compiled against 1.6.0 and still the same accelerometer comm error 

- Sat Mar 09, 2019 1:30 pm
- Forum: Troubleshooting
- Topic: Rostock v2 with probe keeps rebooting fw.92.2
- Replies: 11
- Views: 8520
Re: Rostock v2 with probe keeps rebooting fw.92.2
I compiled against 1.6.0 and still the same accelerometer comm error 

- Sat Mar 09, 2019 1:22 pm
- Forum: Troubleshooting
- Topic: Rostock v2 with probe keeps rebooting fw.92.2
- Replies: 11
- Views: 8520
Re: Rostock v2 with probe keeps rebooting fw.92.2
Thanx for the reply, okay, rewired everything and it doesnt reboot anymore, starts normally, now, and in the terminal I see this: start Info:Autoleveling enabled Transformation matrix: 1.000000 0.000000 0.000000 0.000000 1.000000 0.000000 0.000000 0.000000 1.000000 Free RAM:770 Autoretract:0 X:0.00 ...
- Fri Mar 08, 2019 11:25 pm
- Forum: Troubleshooting
- Topic: Rostock v2 with probe keeps rebooting fw.92.2
- Replies: 11
- Views: 8520
Rostock v2 with probe keeps rebooting fw.92.2
A couple of days ago I bought a HOTEND ACCELEROMETER PROBE PCB BOARD REV 6A for my rostock v2, I made the replacement, with the firmware version 0.92.2 is showing some blue leds and when I turn the temperature on, it turns red, which I believe is okay, however if I go to the firmware and modify the ...