Search found 5 matches
- Fri Aug 09, 2019 11:26 pm
- Forum: Artemis
- Topic: Artemis 300 RTP Z-Probe 1000, No Blue Light, Can't Probe/Map/Level
- Replies: 1
- Views: 3133
Re: Artemis 300 RTP Z-Probe 1000, No Blue Light, Can't Probe/Map/Level
I found the problem: in the 10-pin Molex connector on the hotend PCB, the black 26 AWG wire broke where it goes into the crimped connector, and the orange one was hanging on by one strand. The kit assembly instructions show a zip tie strain relief holding the harness loop to the PCB between the ...
- Fri Aug 09, 2019 11:21 pm
- Forum: Troubleshooting
- Topic: RESOLVED: Z probe issues after recalibration
- Replies: 11
- Views: 11672
Re: RESOLVED: Z probe issues after recalibration
I found the problem with mine: in the 10-pin Molex connector on the hotend PCB, the black 26 AWG wire broke where it goes into the crimped connector, and the orange one was hanging on by one strand. The kit assembly instructions show a zip tie strain relief holding the harness loop to the PCB ...
- Thu Aug 08, 2019 9:53 am
- Forum: Troubleshooting
- Topic: RESOLVED: Z probe issues after recalibration
- Replies: 11
- Views: 11672
Re: RESOLVED: Z probe issues after recalibration
I sent them an email, thanks.
- Wed Aug 07, 2019 4:46 pm
- Forum: Troubleshooting
- Topic: RESOLVED: Z probe issues after recalibration
- Replies: 11
- Views: 11672
Re: RESOLVED: Z probe issues after recalibration
I'm having similar issues with my V3 upgraded to V3.2. My first calibration went fine but now, several days later, I get bed crashes and failed calibrations. It seems to have gotten worse over time, and after a hot end disassembly to fix a jamming problem. The blue light indicating a probe trigger ...
- Wed Aug 07, 2019 4:15 pm
- Forum: Artemis
- Topic: Artemis 300 RTP Z-Probe 1000, No Blue Light, Can't Probe/Map/Level
- Replies: 1
- Views: 3133
Artemis 300 RTP Z-Probe 1000, No Blue Light, Can't Probe/Map/Level
We've had issues with probing/bed mapping/leveling on this machine since the beginning (2 months ago), but were able to get one successful calibration after deleting the config-override file. Since then, I've successfully printed 15 or 20 test pieces which look good but are undersized in the x-y ...