by bryan
Fri Aug 09, 2019 11:26 pm
Forum: Artemis
Topic: Artemis 300 RTP Z-Probe 1000, No Blue Light, Can't Probe/Map/Level
Replies: 1
Views: 3133

Re: Artemis 300 RTP Z-Probe 1000, No Blue Light, Can't Probe/Map/Level

I found the problem: in the 10-pin Molex connector on the hotend PCB, the black 26 AWG wire broke where it goes into the crimped connector, and the orange one was hanging on by one strand. The kit assembly instructions show a zip tie strain relief holding the harness loop to the PCB between the ...
by bryan
Fri Aug 09, 2019 11:21 pm
Forum: Troubleshooting
Topic: RESOLVED: Z probe issues after recalibration
Replies: 11
Views: 11672

Re: RESOLVED: Z probe issues after recalibration

I found the problem with mine: in the 10-pin Molex connector on the hotend PCB, the black 26 AWG wire broke where it goes into the crimped connector, and the orange one was hanging on by one strand. The kit assembly instructions show a zip tie strain relief holding the harness loop to the PCB ...
by bryan
Thu Aug 08, 2019 9:53 am
Forum: Troubleshooting
Topic: RESOLVED: Z probe issues after recalibration
Replies: 11
Views: 11672

Re: RESOLVED: Z probe issues after recalibration

I sent them an email, thanks.
by bryan
Wed Aug 07, 2019 4:46 pm
Forum: Troubleshooting
Topic: RESOLVED: Z probe issues after recalibration
Replies: 11
Views: 11672

Re: RESOLVED: Z probe issues after recalibration

I'm having similar issues with my V3 upgraded to V3.2. My first calibration went fine but now, several days later, I get bed crashes and failed calibrations. It seems to have gotten worse over time, and after a hot end disassembly to fix a jamming problem. The blue light indicating a probe trigger ...
by bryan
Wed Aug 07, 2019 4:15 pm
Forum: Artemis
Topic: Artemis 300 RTP Z-Probe 1000, No Blue Light, Can't Probe/Map/Level
Replies: 1
Views: 3133

Artemis 300 RTP Z-Probe 1000, No Blue Light, Can't Probe/Map/Level

We've had issues with probing/bed mapping/leveling on this machine since the beginning (2 months ago), but were able to get one successful calibration after deleting the config-override file. Since then, I've successfully printed 15 or 20 test pieces which look good but are undersized in the x-y ...

Go to advanced search