- Location: west ohio
HE280 question
Got home from MRRF Sunday this morning at 1:30-sh am. Woke up and upgraded my Max's hot end. It's all wired up and seems to be working, but is the hot end fan supposed to run all the time?
Never do anything you don't want to have to explain to the paramedics.
-
- Printmaster!
- Posts: 191
- Joined: Fri Mar 06, 2015 8:56 pm
Re: HE280 question
Yes. They needed an extra wire for the sensor and so stole it from the fan and then connected the fan up to power so that it would always run.
Dale
Dale
- barry99705
- Printmaster!
- Posts: 707
- Joined: Sun Aug 11, 2013 6:10 pm
- Location: west ohio
Re: HE280 question
Cool! Now I just need to figure out how to make it stop vibrating... 

Never do anything you don't want to have to explain to the paramedics.
-
- ULTIMATE 3D JEDI
- Posts: 1407
- Joined: Sun May 11, 2014 6:18 pm
Re: HE280 question
You can run an extra wire and have it controlled,,,, Here's Mhackney's post http://forum.seemecnc.com/viewtopic.php ... 6&start=75
R-Max V2
Eris
Folger Tech FT-5 R2
Eris
Folger Tech FT-5 R2
- barry99705
- Printmaster!
- Posts: 707
- Joined: Sun Aug 11, 2013 6:10 pm
- Location: west ohio
Re: HE280 question
I'd have to take it apart again! 

Never do anything you don't want to have to explain to the paramedics.
-
- ULTIMATE 3D JEDI
- Posts: 1407
- Joined: Sun May 11, 2014 6:18 pm
- barry99705
- Printmaster!
- Posts: 707
- Joined: Sun Aug 11, 2013 6:10 pm
- Location: west ohio
Re: HE280 question
Swapped out the fan with one of the others. Still whistles, but it's not vibrating, I can handle that. With the door of the enclosure closed it's not too bad.
Never do anything you don't want to have to explain to the paramedics.
- barry99705
- Printmaster!
- Posts: 707
- Joined: Sun Aug 11, 2013 6:10 pm
- Location: west ohio
Re: HE280 question
Wow this thing jams easy!
Never do anything you don't want to have to explain to the paramedics.
-
- Printmaster!
- Posts: 191
- Joined: Fri Mar 06, 2015 8:56 pm
Re: HE280 question
That usually means one of two things. You have the retraction too big when using abs or you did not get the bowden tube seated properly. Usually it is the latter.
Dale
Dale
- barry99705
- Printmaster!
- Posts: 707
- Joined: Sun Aug 11, 2013 6:10 pm
- Location: west ohio
Re: HE280 question
Yea, I think it was the bowden. I have a flying extruder, and the bowden I had with the E3d before was probably an inch too short, so it was pulling on the hot end. I cut a new piece and installed it after I got the clog out. I even used Andy's trick of unscrewing the bowden connector a couple turns, insert the tube, then tighten it back. The new tube should help I think.
Never do anything you don't want to have to explain to the paramedics.
- barry99705
- Printmaster!
- Posts: 707
- Joined: Sun Aug 11, 2013 6:10 pm
- Location: west ohio
Re: HE280 question
I'm starting to not like this hot end....
Code: Select all
22:19:08.984 : Error:One heater seems decoupled from thermistor - disabling all for safety!
22:19:08.984 : Error:Temp. raised to slow. Rise = -1.93 after 46027 ms
22:19:25.508 : extruder 0: working
22:19:25.508 : heated bed: working
22:19:25.508 : Error:Printer set into dry run mode until restart!
22:19:27.686 : extruder 0: working
22:19:27.686 : heated bed: working
22:19:27.689 : Error:Printer set into dry run mode until restart!
22:19:28.170 : extruder 0: working
22:19:28.170 : heated bed: working
22:19:28.174 : Error:Printer set into dry run mode until restart!
22:19:50.064 : extruder 0: working
22:19:50.064 : heated bed: working
22:19:50.069 : Error:Printer set into dry run mode until restart!
22:19:50.069 : extruder 0: working
Never do anything you don't want to have to explain to the paramedics.
- thechewiestbacca
- Printmaster!
- Posts: 50
- Joined: Tue Dec 27, 2016 5:53 pm
Re: HE280 question
Looks like a blown Thermal Safety Fuse. That happened to me, and that's the same error message I got
- barry99705
- Printmaster!
- Posts: 707
- Joined: Sun Aug 11, 2013 6:10 pm
- Location: west ohio
Re: HE280 question
I can reset the printer and it will work again though. I printed the whip clip Steve posted on repables just to make sure it wasn't a temp disconnect with the wires. It printed just fine. I tried printing the part that it errored out on, and it did it again, at layer 8 of 23. Could it be those janky crimps working loose when they get hot?
Never do anything you don't want to have to explain to the paramedics.
- barry99705
- Printmaster!
- Posts: 707
- Joined: Sun Aug 11, 2013 6:10 pm
- Location: west ohio
Re: HE280 question
https://goo.gl/photos/yj4c94gUPjmen4Nt7
Seems to be dieing off around the same place. Printed from the pc and from sd card, so not the connection between. Getting DEF for both temps. I've resliced it with each version, so I don't think it's the gcode.
Seems to be dieing off around the same place. Printed from the pc and from sd card, so not the connection between. Getting DEF for both temps. I've resliced it with each version, so I don't think it's the gcode.
Never do anything you don't want to have to explain to the paramedics.
- barry99705
- Printmaster!
- Posts: 707
- Joined: Sun Aug 11, 2013 6:10 pm
- Location: west ohio
Re: HE280 question
Took the whole thing apart and recrimped everything. Made it to layer 12 this time, but did the same thing.
Can the fuses be intermittent?
Code: Select all
13:39:40.747 : Printing layer 12 of 34
13:43:47.506 : Error:One heater seems decoupled from thermistor - disabling all for safety!
13:43:47.507 : Error:Temp. raised to slow. Rise = -2.18 after 46027 ms
Never do anything you don't want to have to explain to the paramedics.
- barry99705
- Printmaster!
- Posts: 707
- Joined: Sun Aug 11, 2013 6:10 pm
- Location: west ohio
Re: HE280 question
Turns out, the hotend is very susceptible to the part fans. I'm using the same effector as my e3d which has 3 built in axial fans. I think the new hotend sticks down farther than the e3d did, so it's right in the path of the cooling air. Watching the temperature graph, when the fans kicked on, it would drop almost 15 degrees, and then trip the firmware.
Never do anything you don't want to have to explain to the paramedics.