my heated bed is showing a 12 degree difference between my thermocouple on my meter and the thermistor in the bed. this is with the glass on. is there a line in the config,h for the bed that will allow a change like you can do with the hotend.
Tom C
heated bed calibration
-
- Printmaster!
- Posts: 345
- Joined: Mon Jan 06, 2014 1:24 am
heated bed calibration
MAX V1
325 MM carbon arms trick trucks effector mount LED ring heat spreader
Corvair750
V6 Hotend
Robo 3D
Flashforge creator
http://WWW.TeslagenX.com" onclick="window.open(this.href);return false; - Bedini experimenter kits, books, DVD's
325 MM carbon arms trick trucks effector mount LED ring heat spreader
Corvair750
V6 Hotend
Robo 3D
Flashforge creator
http://WWW.TeslagenX.com" onclick="window.open(this.href);return false; - Bedini experimenter kits, books, DVD's
Re: heated bed calibration
The top of the glass could be 12 degs colder.
When on mobile I am brief and may be perceived as an arsl.
-
- Printmaster!
- Posts: 345
- Joined: Mon Jan 06, 2014 1:24 am
Re: heated bed calibration
well that sucks. I know there will be some difference, but that puts the edges of the bed to around 60, anything below 70 and I get curling on the edges with abs. I guess after I crank it up to 24 volts (still have not gotten my second SSR from amazon) I will just have to run the temp up until it actually is hot enough on the perimeter.
Tom C
Tom C
MAX V1
325 MM carbon arms trick trucks effector mount LED ring heat spreader
Corvair750
V6 Hotend
Robo 3D
Flashforge creator
http://WWW.TeslagenX.com" onclick="window.open(this.href);return false; - Bedini experimenter kits, books, DVD's
325 MM carbon arms trick trucks effector mount LED ring heat spreader
Corvair750
V6 Hotend
Robo 3D
Flashforge creator
http://WWW.TeslagenX.com" onclick="window.open(this.href);return false; - Bedini experimenter kits, books, DVD's
Re: heated bed calibration
I was wondering the same thing. Why is there a process for calibrating the hotend, but no calibration process for the heated bed?
Re: heated bed calibration
The heated bed calibration use to be in the manual (last revision I think), not sure why it was pulled.
I believe this is the correct code for 80c. M303 P1 S80
Edit, didnt mean 180
I believe this is the correct code for 80c. M303 P1 S80
Edit, didnt mean 180

Last edited by KAS on Wed Jun 24, 2015 1:52 pm, edited 1 time in total.
-
- ULTIMATE 3D JEDI
- Posts: 2417
- Joined: Mon Mar 26, 2012 1:44 pm
- Location: Redmond WA
Re: heated bed calibration
You can change the thermistor type to be custom, calculated from a Beta value, then tweak that beta value to match the actual temperature in the range you usually measure.
I do this with my hot-end, though mostly because the thermistors supplied with the E3D hotends I have were miles off.
I usually don't bother with the bed, I just know that with it set to 80C whatever the actual temperature is sufficient to print with ABS, 60C for PLA etc.
I do this with my hot-end, though mostly because the thermistors supplied with the E3D hotends I have were miles off.
I usually don't bother with the bed, I just know that with it set to 80C whatever the actual temperature is sufficient to print with ABS, 60C for PLA etc.
Printer blog http://3dprinterhell.blogspot.com/
Re: heated bed calibration
Thanks. I'll try that. My fan shroud came off the bed about 75% of the way through my first ever print, so I'm concerned the temperature was lower than it needed to be for good adhesion.KAS wrote:The heated bed calibration use to be in the manual (last revision I think), not sure why it was pulled.
I believe this is the correct code for 80c. M303 P1 S80
Edit, didnt mean 180 :)