Code: Select all
->N7814 M105*29 [1369.345]
<-ok 7814 [1369.904]
<- [1369.904]
->N7815 G1 X-30.49 Y-1.57 Z1.811 E1404.942 F360*84 [1369.906]
<-T:230.10 /228 B:76.62 /100 B@:255 @:145 [1369.908]
<- [1369.908]
<-ok 7815 [1369.913]
<- [1369.913]
->N7816 G1 X-30.02 Y-6.42 Z1.811 E1405.246 F360*85 [1369.914]
<-Error:One heater seems decoupled from thermistor - disabling all for safety! [1370.311]
<- [1370.311]
<-Error:Temp. raised to slow. Rise = -3.32 after 301018 ms [1370.311]
<- [1370.311]
<-ok 7816 [1370.470]
<- [1370.470]
->N7817 M105*30 [1370.471]
<-ok 7817 [1370.678]
So, I'm a new user. The display is showing just over 3 days of use. The bed has never really heated well. I usually start a job at 80C, then when it starts, bump it to 100C, which it may never be able to hold. I'm going to do some troubleshooting to check the voltage at the plate, and the voltage selector on the power supply. Barring that, I see that there's a max PWM value that can be changed in the firmware. Suggestions are welcome.
However, I saved my log file, and am trying to decode the temperature replies. I see M105*xx, and haven't been able to find the definition for the response. Is this Repetier? Rambo? Is Rambo the hardware that can run various firmwares? Is there an architecture diagram that shows how everything is composed?