New Nozzle Height when Probing

Having a problem? Post it here and someone will be along shortly to help
Post Reply
ComJak
Prints-a-lot
Posts: 24
Joined: Sun Oct 02, 2016 1:07 am

New Nozzle Height when Probing

Post by ComJak »

I just installed the E3D .35 Brass Nozzle onto the Rostock v3. As you may know, the E3D nozzle sticks out a lot more than the stock nozzle. When I run the probing gcode, I'm now having about a 40-50% chance of the nozzle ramming into the glass and the code not stopping the motors. Instead, it skips a couple of belt teeth before crashing out and attempting the probe again. I assume this is because the new height of the nozzle.

What value do I need to change to reduce this crashing and belt skipping? The belt is properly tightened.

Thanks,
User avatar
Jimustanguitar
ULTIMATE 3D JEDI
Posts: 2608
Joined: Sun Mar 31, 2013 1:35 am
Location: Notre Dame area
Contact:

Re: New Nozzle Height when Probing

Post by Jimustanguitar »

Change the Z height of the whole machine in the EEPROM, I'd imagine.
Qdeathstar
Printmaster!
Posts: 622
Joined: Wed Apr 13, 2016 7:42 pm

Re: New Nozzle Height when Probing

Post by Qdeathstar »

I don't think that is likely to be the issue because the z-probe probes for differences in z-height and uses those differences to calibrate.


I think it's more likely there's a loose wire in your setup; the psON one maybe since that's the interrupt
Post Reply